Address: Mariannengasse 17, 1090 Vienna, Austria Office Open: 8.00 am - 4.00 pm Email: office@carlreiner.eu

TwinStream EVO

TwinStreamTM EVO jet ventilator:

A new generation

TwinStreamTM EVO is the newest addition to our range of jet ventilators and embodies more than 35 years of expertise in jet ventilation. Its modern design, user-friendly interface and 15.6" touchscreen display make for a seemless integration into any hospital environment.

Shared airway procedures

Just like its predecessor the TwinStreamTM EVO provides an unparalleled solution for procedures in a shared airway, when both surgeon and anaesthetist require access to the same upper airway (Laryngotracheal surgery) or lower airway (Interventional Pulmonology or Thoracic surgery).

Reduced respiratory motion

The TwinStreamTM EVO can also provide S-HFJVTM to conventionally intubated patients to immobilise the thorax and/or abdomen in Interventional Radiology, Interventional Cardiology or Interventional Urology. S-HFJVTM can reduce respiratory motion to a minimum, while assuring sufficient CO2 elimination, even during e.g. 5+ hour procedures.

'Superimposed' HFJV

The unique combination of high-frequency (50-2000/min) and low-frequency ventilation (1-120/min) provides both optimal oxygenation and efficient CO2 elimination at the same time. This is why Superimposed High-Frequency Jet Ventilation (S-HFJVTM) can be used without any time limit.

TwinStream EVO

Advanced monitoring in an open airway:

TwinStream EVO

Airway pressures & gas concentrations

  •   PIP
  •   PEEP
  •   Mean PAW
  •   Δp HF
  •   FiO2 jet
  •   FiO2 AW
  •   cCO2
  •   EtCO2

TwinStreamTM EVO video:

TwinStreamTM EVO configurations:

Single jet (HFJV):

  •   High-frequency jet ventilation
  •   Fully accessible airway
  •   Superior oxygenation
  •   1/2-lumen jet catheters
  •   PP monitoring
  •   Gas monitoring in airway
  •   Laser Safe Mode (LSM)
  •   Automatic pressure alarm
Jet catheter

Double jet (S-HFJVTM):

  •   High-frequency jet ventilation
  •   Low-frequency jet ventilation
  •   Fully accessible airway
  •   Superior oxygenation
  •   CO2 elimination
  •   Customised jet endoscopes
  •   3/4-lumen jet catheters
  •   PIP, PEEP, Mean PAW and Δp HF monitoring
  •   Continuous O2 and CO2 monitoring
  •   Laser Safe Mode (LSM)
  •   Automatic pressure alarm
Jet laryngoscope

Shared airway procedures:

Jet Ventilation in ENT


Laryngotracheal surgery

Infraglottic jet ventilation allows for laryngotracheal surgery (e.g. tumor resection, polyp removal, cyst removal, etc.) by means of a thin (laser-resistant) Jet Catheter, ranging from 1 to 4 lumens (OD 2.7 - 6.6 mm).

Tubeless supraglottic jet ventilation allows for optimal laryngotracheal surgery without endotracheal tube or jet catheter restricting the surgeon’s view and access. Even a challenging (sub)glottic stenosis can easily be treated supraglottically.

Laser Safe Mode (LSM) reduces the oxygen concentration in the airway down to the exact desired level to avoid any risk of airway fires.

Interventional Pulmonology_WEBSITE


Interventional Pulmonology

A jet bronchoscope or jet tracheobronchoscope comes with integrated channels for double jet ventilation, airway pressure monitoring and gas monitoring.

At the same time the 'open' jet endoscope provides optimal airway access for a wide array of shared airway procedures such as e.g.:

• restoring airway patency:
   - laser surgery
   - electrocautery
   - cryotherapy
   - argon plasma coagulation
   - stent placement
• foreign bodies removal
• endobronchial ultrasound (EBUS)
• navigational bronchoscopy (CBCT)
• airway bleeding managment

Thoracic_surgery_TS_EVO_WEBSITE


Thoracic surgery

Several different types of jet catheters, ranging from 1 to 4 lumens, allow for shared airway procedures such as e.g. various resections (trachea, carina, pleura, lobe or lung).

A combination of Jet Converter and jet catheter allows switching from a wide endotracheal tube to a tiny jet catheter and back. During e.g. a tracheal resection this provides the surgeon with optimal working space when required.

During Single-Lung Ventilation the Jet Converter connects to a Double-Lumen Tube to gently ventilate the operated lung. HFJV provides optimal oxygenation, while its frequency range (up to 2000/min) reduces any lung motion to an absolute minimum.

Reduced respiratory motion:

Interventional Radiology_TS_EVO_WEBSITE


Interventional Radiology

During tumour ablation the exact targeting of the tumour is essential for the accuracy of the therapeutic effect, as well as to avoid collateral damage of healthy tissue.

High-Frequency Jet Ventilation (HFJV) can attain a frequency as high as 2000/min, effectively reducing the respiratory motion to virtually nothing.

Superimposed High-Frequency Jet Ventilation (S-HFJVTM) allows for optimal reduction of respiratory motion in the thoracoabdominal environment, while still guaranteeing optimal CO2 elimination, especially during longer procedures, which may take up to 4-5 hours.

Interventional Cardiology_TS_EVO_WEBSITE


Interventional Cardiology

During treatment of cardiac arrhythmia by means of radiofrequency ablation (RFA) the stability of the contact force between catheter tip and cardiac tissue is of crucial importance.

Compared to conventional ventilation High- Frequency Jet Ventilation (HFJV) is known to improve the stability of this contact significantly.

Superimposed High-Frequency Jet Ventilation (S-HFJVTM) allows for optimal reduction of respiratory motion in the thoracoabdominal environment, while still guaranteeing optimal CO2 elimination, especially during longer procedures, which may take up to 4-5 hours.

TwinStream jet ventilator in urology


Interventional Urology

During kidney stone treatment by means of shock wave lithotripsy the accuracy of the stone targeting can be increased by means of High-Frequency Jet Ventilation.

High-Frequency Jet Ventilation (HFJV) can attain a frequency as high as 2000/min, effectively reducing the respiratory motion to virtually nothing.

Superimposed High-Frequency Jet Ventilation (S-HFJVTM) allows for optimal reduction of respiratory motion in the thoracoabdominal environment, while still guaranteeing optimal CO2 elimination, especially during longer procedures.

TwinStreamTM EVO accessories:

Jet laryngoscope

Jet Laryngoscope

Integrated ventilation & monitoring

Jet bronchoscope

Jet Bronchoscope

Integrated ventilation & monitoring

Jet Converter

Integrated ventilation & monitoring

  • Address: Mariannengasse 17, 1090 Vienna
  • Phone number: +43 1 402 62 51 0